For the purpose of pipeline design and installations parallel or crossing municipal road allowances, the following conditions shall apply:
-
all road allowances are deemed to be 45.72 meters (150 feet);
-
all pipelines must be installed at right angles to the road allowance;
-
pipelines should cross road allowances at the low spots where ever possible;
-
minimum pipeline depth shall be 2.5 meters (8 feet) in low spots and 3.7 meters (12 feet) in high spots on the road allowance;
-
all developed roads must be punched through;
-
encasement and vents are required on all high traffic roads or other roads as deemed necessary by Council;
-
vents may be placed on the outer edge of the existing right of way but will require moving at such times as road widening or construction occurs.